ASME B16.5 Flange Pressure-Temperature Rating Calculator

ASME B16.5 Table 2 (Phase-1: Groups 1.1 & 2.2)
Loading calculator…

Indexable specification URLs

Self-referencing canonical pages for common field sizes and ratings. Each link is a clean path (no query string) included in sitemap.xml.

Engineering Reference & ASME Code Basis

1. Core Formula & Variable Definitions

ASME B16.5 — Pipe Flanges and Flanged Fittings (NPS ½–24) · ASME B16.5 Table 2 — Pressure-Temperature Ratings (Groups 1.1 & 2.2 Phase-1 extract) · ASME B31.3 (2022 Edition) · — Process Piping (related wall-thickness screening)

P = P1 + ((TT1)/(T2T1)) · (P2P1)

Phydro = 1.5 · Pambient (−29…38 °C)

ASME B16.5 Table 2 Pressure-Temperature Ratings · Phase-1 Groups 1.1 & 2.2

Groups 1.1 · 2.2Classes 150–2500 (Phase-1)Hydro 1.5 × ambientScope B16.5 NPS ≤ 24

Working pressure is taken from ASME B16.5 Table 2 for the selected material group and flange class. Intermediate temperatures use linear interpolation between published nodes. Hydrostatic shell test pressure is 1.5 × the ambient (−29…38 °C) rating. Phase-1 data: Group 1.1 Classes 150–2500 and Group 2.2 Classes 150/300/600. Scope is NPS ½–24 (B16.5); B16.47 large-diameter flanges are excluded.

  • T (Design Temperature)Metal temperature used to enter Table 2 (°C / °F).
  • P (Working Pressure Rating)Maximum allowable working pressure from Table 2 (bar / psi / MPa).
  • P_ambient (Ambient Rating)Table 2 rating for the −29…38 °C band.
  • P_hydro (Hydrostatic Shell Test)1.5 × ambient rating (screening).
  • Group (Material Group)B16.5 material group (Phase-1: 1.1 carbon steel, 2.2 316/316L).
  • Class (Flange Class)Pressure class designator 150 / 300 / 600 / 900 / 1500 / 2500.

2. Allowances, Tolerances & Standards

Use official ASME B16.5 tables for stamped design. This tool is a Phase-1 screening extract with linear interpolation.

Linear interpolationP between T₁ and T₂

When design temperature falls between published nodes, MAWP is linearly interpolated in °C / bar space.

Hydrostatic shell test1.5 × P_ambient

Screening hydrotest pressure uses the ambient (−29…38 °C) rating, not the derated elevated-temperature rating.

B16.5 size limitNPS ≤ 24

Larger flanges follow ASME B16.47 and are outside this calculator.

Class 150 high temperature> 538 °C / 1000 °F

Class 150 service above 538 °C requires confirmation against B16.5 notes and owner specification.

Quick Reference Lookup Table

ASME B16.5 Group 1.1 carbon steel MAWP (bar) — Class 150 / 300 / 600 scan chart
T (°C)Class 150Class 300Class 600
−29…3819.651.1102.1
5019.250.1
10017.746.492.8
15015.845.2
20014.043.887.6
25012.141.9
30010.239.879.6
3508.437.6
4006.534.769.4
4504.723.046.0
5002.811.322.5
5381.45.611.3

Values from the Phase-1 FEK extract of ASME B16.5 Table 2-1.1. Class 600 rows marked — use nearest published nodes with linear interpolation in the live calculator. Group 2.2 and Classes 900–2500 are available in the interactive tool.

3. Material & Code Limitations

Only Groups 1.1 and 2.2 are loaded. Additional Table 2 groups require a later data release.

Material GroupTemperature RangeAllowable Stress / LimitEngineering Notes
Group 1.1 — Carbon Steel−29…538 °CClasses 150–2500Typical specs: ASTM A105, A106 Gr.B, A350 LF2.
Group 2.2 — Stainless 316/316L−29…538 °CClasses 150 / 300 / 600Typical specs: ASTM A182 F316 / F316L. Classes 900–2500 not in Phase-1.

Code Applicability & Safety Boundaries

  • Do not apply these ratings to ASME B16.47 Series A/B flanges.
  • Confirm edition year of the project B16.5 table before stamping MAWP.

4. Step-by-Step Worked Example

Field VerificationShow

Worked Example — Group 1.1 Class 150 @ 125 °C

Carbon steel Class 150 flange at 125 °C (between 100 °C = 17.7 bar and 150 °C = 15.8 bar).

Material group:1.1 (A105)Flange class:150Design temperature:125 °C
1

Locate bounding nodes

T₁ = 100 °C, P₁ = 17.7 bar; T₂ = 150 °C, P₂ = 15.8 bar.
Result:Bracket identified
2

Linear interpolation

P = 17.7 + (125−100)/(150−100)×(15.8−17.7) = 17.7 − 0.95 = 16.75 bar.
Result:MAWP ≈ 16.8 bar
3

Hydrotest pressure

P_ambient = 19.6 bar → P_hydro = 29.4 bar.
Result:P_hydro = 29.4 bar
Conclusion: Report MAWP ≈ 16.8 bar at 125 °C and hydrotest 29.4 bar. Confirm against the project ASME B16.5 edition before design acceptance.

5. Frequently Asked Questions & Technical References

Show

No. Class is a dimensionless designator. MAWP depends on material group and temperature per ASME B16.5 Table 2 (e.g. Group 1.1 Class 150 ≈ 19.6 bar at 38 °C, much lower at elevated temperature).